Eaton Rigid Tube Assembly Repair


Tuesday, April 21, 2026
to Wednesday, April 22, 2026

Competitors Required:

2

Description:

Competitors will repair a rigid tube assembly using the Rynglok Axial Swage Tube Fitting System.

References:

  • Eaton bulletin TF100-138 Rynglok Tube Fitting System assembly procedure and inspection guide
  • Eaton bulletin TF100-1F Rynglok Fitting System Design Features and product overview
  • Eaton bulletin TF100-75 Rynglok Fitting System AS-Standards Cross Reference
  • AS5958 Fittings, Axial Swaged Tube with Flareless Separable, Fitting System 5080 psi Specification
  • US Navy NAVAIR 01-1A-20 Hydraulic hose and tube manual US Airforce TO 42E1-1-1 Hydraulic hose and tube manual

Tools, Equipment, and Materials Provided:

See Eaton Bulletin TF100-138.

 

Snap-on provided tooling (qty one in each of two pallets unless otherwise indicated): None

Procedures:

See Eaton Bulletin TF100-138

 

Penalties will be assessed for:

  • Step 1 – Not selecting the correct RTSGO-01-08 Tool from the tool kit.
  • Step 1 – Not marking tube correctly using RTSGO-01-08 Tool and marking pen.
  • Step 2 – Not inserting the fitting to the correct depth on the tube per the position mark.
  • Step 3 – Not selecting the correct size tool from the tool kit.
  • Step 5 – Not swaging the fitting correctly and not passing the visual inspection using gauge RTSGO-51-08.

Last Updated: 12/17/2025

Sample Score Sheet

For More Information:

Jeff Askam

Jeff Askam

Regional Account Director, Eaton - Rigid Tube Assembly Repair

View Profile